FOR RESEARCH PURPOSES ONLY — NOT FOR HUMAN CONSUMPTION
Free Shipping from 100 EUR/ COA Verified — Third Party Tested/ Fast EU Delivery — Ships from Europe/ cGMP Certified Supplier/ Trusted by Research Professionals/ >98% Purity Guaranteed/ Free Shipping from 100 EUR/ COA Verified — Third Party Tested/ Fast EU Delivery — Ships from Europe/ cGMP Certified Supplier/ Trusted by Research Professionals/ >98% Purity Guaranteed/
Shop All Performance & Recovery Anti-Aging & Longevity Research About Terms Privacy
PRODUCT PHOTO
ACCESSORY

Bacteriostatic Water

30ml Vial — USP Grade

EUR 12
USP Grade Sterility Tested 0.9% Benzyl Alcohol
BUY NOW

Description

Bacteriostatic Water for Injection (BWFI) is sterile water containing 0.9% benzyl alcohol as a bacteriostatic preservative, manufactured in compliance with United States Pharmacopeia (USP) standards. It is the standard diluent used in research laboratories for the reconstitution of lyophilized peptides and other lyophilized compounds. The 30ml vial size provides sufficient volume for reconstituting multiple peptide vials, making it an essential supply item for any peptide research program.

The 0.9% benzyl alcohol concentration serves a critical function: it inhibits the growth of bacteria and other microorganisms that could contaminate the solution after the vial septum has been punctured. Unlike sterile water for injection, which is intended for single-use only and must be discarded after the seal is broken, bacteriostatic water can be safely used multiple times over a period of up to 28 days after initial puncture. This multi-use capability is what makes it the preferred reconstitution medium in research settings where multiple peptide vials may need to be prepared over the course of several weeks.

The reconstitution process for lyophilized peptides using bacteriostatic water follows established laboratory protocols. Using a sterile syringe, the appropriate volume of bacteriostatic water is drawn from the vial and gently introduced along the wall of the peptide vial, allowing the water to flow down onto the lyophilized powder without direct force. The peptide vial should then be gently swirled — never shaken vigorously — to dissolve the powder completely. Most research peptides dissolve within 1-3 minutes using this technique. The resulting solution should be clear and free of visible particulates. If cloudiness or undissolved material persists, the vial should be allowed to sit at room temperature for several minutes before gently swirling again.

Compatibility with research peptides is broad. Bacteriostatic water is the recommended reconstitution medium for BPC-157, TB-500, CJC-1295, Ipamorelin, Epithalon, GHK-Cu, and virtually all other lyophilized research peptides. The benzyl alcohol preservative has been extensively tested for compatibility with peptide structures at the 0.9% concentration and does not cause degradation or denaturation of properly stored reconstituted peptide solutions. However, some particularly sensitive proteins or peptide fragments may require sterile water without preservative — researchers should consult specific product documentation when working with novel compounds.

Proper technique when accessing the vial is essential for maintaining sterility. Before each use, the rubber septum should be swabbed with 70% isopropyl alcohol and allowed to air dry completely. A new sterile syringe and needle should be used for each draw to prevent cross-contamination between different peptide preparations. The needle should be inserted at a slight angle through the septum center, and an equivalent volume of air should be injected into the vial before withdrawing liquid to prevent vacuum formation. This product is manufactured under cGMP conditions, with each batch undergoing sterility testing, endotoxin testing, and benzyl alcohol concentration verification.

Composition

Storage

Certificate of Analysis

Every batch of Bacteriostatic Water sold by Pepspan undergoes comprehensive quality testing. Our Certificate of Analysis (COA) includes sterility testing (USP <71>), bacterial endotoxin testing (USP <85>), benzyl alcohol concentration verification, pH measurement, particulate matter testing (USP <788>), and container closure integrity testing. COA documentation is available upon request for any batch number. All testing is performed by independent European laboratories under GMP standards.

Batch Purity Report

Janoshik Verified

Current Batch: Pending first shipment

Every batch of Bacteriostatic Water sold by Pepspan is independently tested by Janoshik Analytical (Prague, Czech Republic). HPLC purity analysis, mass spectrometry, and amino acid sequencing are performed for each shipment. Reports are batch-specific — not generic.

View All Purity Reports →

Research Disclaimer

This product is intended for laboratory research use only. It is not intended for direct injection into humans or animals outside of approved research protocols. Bacteriostatic water is a laboratory supply item used for the reconstitution of lyophilized research compounds. By purchasing this product, you confirm that you are a qualified researcher and that this product will be used exclusively for legitimate scientific research purposes. Pepspan assumes no liability for any misuse of this product. All handling must comply with local regulations and institutional safety protocols.